GREENPOWER Iveco FPT Diesel Power generator 75kVA 60kW Soundproof canopy Automatic starting  




greenpower
Greenpower Equipped with Iveco water-cooled diesel engine. Supplied with stable framework and Green Power electrical panel, voltmeter, frequency meter, ammeter, hour meter, starter key and indicator panel for oil, battery charge and low fuel level.

Specification

  • Prime running power (PRP) 75kVA, 60 kW
  • Emergency stand by power (ESP) 82kVA, 68kW
  • 400/230 V @ 50 Hz 1500 rpm
  • High quality and reliable 4-cylinder Iveco diesel engine
  • Easily operated control panel
  • Brushless permanent magnetized generator IP22 with optional electronic AVR
  • Fuel tank 80 lt

» Click Here to view the Engine Datasheet

» Click here to see Datasheet

Technical Data 
Generator Engine   Iveco FPT NEF N45SM2A
Type 4 cycle, water-cooled, diesel engine
 Landuse Type of Unit   Low Noise, Automation Type
No of Cylinders 4
Cylinders Arrangement In-line
Displacement 4.5 Liters
Bore x Stroke 104 x 132 mm
Prime Rated Power (PRP) 75 kVA/60 kW
Emergency stand by power (ESP) 82 kVA/68 kW
Speed 1500 rpm
Engine Power 98.3/73.3 (Hp/kW)
Fuel Consumption 14.5 liter/hour
Rated Current 108.2 Amps
Rated Voltage 400V/230V
Dimension (LxBxH) 2300 x 1050 x 1590 mm
  Weight   1345 Kg
Fuel tank 120lt
 
 
General Specification for silent Generator :
  • Modular Design
  • Anti Corrosion powder coated
  • Insulated with acoustic foam lining
  • Central lifting ring, exhaust pipe can be removed, which is easy to transport
  • Lockable doors with key
  • Protective mesh for rotating parts
  • Exterior emergency stop push button
  • Thermally insulated engine exhaust system
  • Doors fitted on each side
  • Panel observing window
  • Access to the radiator fill or cap
  • Color is optional
  • Fuel gauge or lube drain valve is optional
  • Normal or super soundproof canopy is optional
  • Base frame fuel tank or profile fuel tank is optional
  • The muffler fixed position depend on the output power of the Gen-set 

Silent Generator set Canopy :

  • Specially treated steel sheet
  • Stainless steel locks
  • Control panel viewing window for monitoring the status of the generator set
  • Good ventilation system and anti-heat radiation saturation
  • Effective anti-vibration devices to ensure generator driven steadily
  • Super silent materials inside to ensure the noise lower than 68 dB 7 meters away
  • Emergency stop button mounted outside
  • Side lockable door easy for maintenance and installation
  • Lube oil and cooling water drain pipe to the exterior of the canopy
  • Fuel tank built with level indicator
 Standard equipment  Other configurations
  • Air inlet system
  • Autostart 
  • Automatic power switch ATS 
  • Automatic power switch and phase-out
  • Automatic fuse
  • Control system
  • Cooling system
  • Fly wheel and flywheel housing
  • Emergency stop button
  • Fuel system
  • Safety device in the engine for:
    • high water temperature
    • low oil pressure
    • low fuel level 
    • battery charging error
  • Models with different voltage
  • 60 Hz version
   
 Accessories
 
  •  Mobile device on wheels 
  •  Type-approved trailer 
  •  Parallel operation 
  •  Fuse type 
  •  Ground fault switch 
  •  Extraction point with current transformers at zero point 
  •  Radiostatic protection VDE 0875 curve N 
  •  Electronic speed control 
  •  Oil heater 
  •  Engine heater 
  •  Oil pump 
  •  Automatic tanker from external tank 
  •  Protective frame with lift hook 
  •  Container unit 
  •  Alternator voltage / frequency generator 
  •  Fuel tank deployment 
  •  Fuel level 
  •  Alarm on all internet connection. 
  •  GSM alarm monitoring 
  •  Capable soundproofing 70dB down to 55dB 
  •  Remote control 
  •  Environmental Class STAGE III 
  •  Disconnect 1-phase or 3-phase, respectively 
  •  UPS system battery backup 1-phase and 3-phase
Standard Genset Specifications
 
Engine
  • Iveco FPT heavy duty diesel engine
  • 4 cylinder equipped with Water cooling
  • Mechanical governor control system
  • Replaceable wet type cylinder liners
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Iveco FPT Engine Manual
 Alternator
  • Brushless, single bearing system
  • Insulation class H with circuit breaker protection
  • Standard degree of protection IP 23
  • Self-exciting and self-regulating
  • Main line ciucuit breaker
  • Close voltage regulation
Greenpower AB reserves the right to make any errors or changes in specifications. © Copyright / Greenpower AB.
  • GREENPOWER Iveco FPT  Diesel Power generator 75kVA 60kW Soundproof canopy Automatic starting
    Art. nr.
    GP75FSAST
    GREENPOWER Iveco FPT Diesel Power generator 75kVA 60kW Soundproof canopy Automatic starting
    Write down the required equipment for quotation :
For more information contact us at
0431-222 90
  Contact   Print