GREENPOWER Perkins Diesel Power generator 180kVA 144kW Open frame Automatic starting  




greenpower

Greenpower Equipped with a water-cooled Perkins diesel engine. Supplied with stable framework and Green Power electrical panel, voltmeter, frequency meter, ammeter, hour meter, starter key and indicator panel for oil, battery charge and low fuel level. We also supply the silenced version as an option.

Specification

  • Prime running power (PRP) 180kVA, 144kW
  • Emergency stand by power (ESP) 200kVA, 160 kW
  • 400/230 V @ 50 Hz 1500 rpm
  • High quality and reliable 6-cylinder Perkins diesel engine
  • Easily operated control panel
  • Brushless permanent magnetized generator IP23 with optional electronic AVR
  • Fuel tank 250 liters with leak protection
 
Technical Data 
Generator Engine   Perkins 1106A-70TAG3
Type 4 cycle, water-cooled, diesel engine
Compression Ratio 16:1
No of Cylinders 6
Cylinders Arrangement In-line
Displacement 7.0 Liters
Bore x Stroke 105 x 135 mm
Prime running power (PRP) 180 kVA/144 kW
Emergency stand by power (ESP) 200 kVA/160 kW
Speed 1500 rpm
Mechanical output 131-192 kWm
Fuel Consumption 39.8 liter/hour
Rated Current 400 Amps
Rated Voltage 400V/230V
Landuse Type of Unit Low Noise, Automation Type
Weight 1740 Kg
Dimension (LxBxH) 2400 x 1100 x 2000 mm
Rotation Anti-clockwise
Fuel tank 250liter with leakage protection
Current 259A
Motor power 216/157 (hp/kW)
Standard tank capcaity 250 l
Sound level 69dB (A)
Frequency 50Hz
 
 
General Specification for silent Generator :
  • Modular Design
  • Anti Corrosion powder coated
  • Insulated with acoustic foam lining
  • Central lifting ring, exhaust pipe can be removed, which is easy to transport
  • Lockable doors with key
  • Protective mesh for rotating parts
  • Exterior emergency stop push button
  • Thermally insulated engine exhaust system
  • Doors fitted on each side
  • Panel observing window
  • Access to the radiator fill or cap
  • Color is optional
  • Fuel gauge or lube drain valve is optional
  • Normal or super soundproof canopy is optional
  • Base frame fuel tank or profile fuel tank is optional
  • The muffler fixed position depend on the output power of the Gen-set 

Silent Generator set Canopy :

  • Specially treated steel sheet
  • Stainless steel locks
  • Control panel viewing window for monitoring the status of the generator set
  • Good ventilation system and anti-heat radiation saturation
  • Effective anti-vibration devices to ensure generator driven steadily
  • Super silent materials inside to ensure the noise lower than 68 dB 7 meters away
  • Emergency stop button mounted outside
  • Side lockable door easy for maintenance and installation
  • Lube oil and cooling water drain pipe to the exterior of the canopy
  • Fuel tank built with level indicator
 Standard equipment  Other configurations
  • Air inlet system
  • Autostart
  • Automatic power switch ATS
  • Automatic power switch and phase-out
  • Automatic fuse magnetothermal
  • Control system
  • Cooling system
  • Fly wheel and flywheel housing
  • Emergency stop button
  • Fuel system
  •  Safety device in the engine for:
    • high water temperature
    • low oil pressure
    • low fuel level 
    • battery charging error
  • Models with different voltage
  • 60 Hz version
   
 Accessories
 
  • Mobile drive wheel
  • Type-approved trailer 
  • Blink-free feedback
  • Parallel operation
  • Fuse type
  • Ground fault switch 
  • Extraction point with power transformer input point
  • Radiostatic protection VDE 0875 curve N
  • Electronic speed control
  • Oil heater
  • Engine heater
  • Oil pump
  • Automatic tanker from external tank
  • Protective frame with lift hook 
  • Container unit 
  • Alternator voltage / frequency generator
  • Fuel tank deployment
  • Fuel level 
  • Alarm on all internet connection.
  • GSM alarm monitoring
  • Capable soundproofing 70dB down to 55dB
  • Remote control
  • Environmental Class STAGE III
  • Disconnect 1-phase or 3-phase, respectively
  • UPS system battery backup 1-phase and 3-phase
Standard Genset Specifications
 
Engine
  • Perkins heavy duty diesel engine
  • 6 cylinder equipped with Water cooling
  • Mechanical governor control system
  • Replaceable wet type cylinder liners
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Perkins Engine Manual
  Alternator
  • Brushless, single bearing system
  • Insulation class H with circuit breaker protection
  • Standard degree of protection IP 23
  • Self-exciting and self-regulating
  • Main line circuit breaker
  • Close voltage regulation

Greenpower AB reserves the right to make any errors or changes in specifications. © Copyright / Greenpower AB.

  • GREENPOWER Perkins Diesel Power generator 180kVA 144kW Open frame Automatic starting
    Art. nr.
    GP180PAS
    GREENPOWER Perkins Diesel Power generator 180kVA 144kW Open frame Automatic starting
    Write down the required equipment for quotation :
For more information contact us at
0431-222 90
  Contact   Print