GREENPOWER Perkins Diesel Power generator 230kVA 184kW Soundproof canopy Automatic starting  




greenpower
Greenpower Equipped with stable framework, Green Power electrical panel, voltmeter, frequency meter, ampere meter, hour meter, key switch and indicator panel for the oil, battery charging and low fuel level. As an option, we also produce the silenced version.

Specification

  • Prime Power(PRP) 184kW 230kVA , Limited Time Power (LTP) 202kW 253kVA  at 230/400v @50hz 1500rpm
  • High quality and reliable 6 cylinder, Perkins diesel engine
  • Ideal for business applications
  • Automatic changeover (ATS), Maintenance Free Batteries and Trickle Charger Included
  • Brushless alternator with AVR provides stable output
  • High temperature and low oil, water and fuel protection to protect against engine damage
  • Easy to use Digital Controller with Auto and Manual Start Options

» Click Here to view the Engine Datasheet

» Click here to see Datasheet

Technical Data 
Generator Engine  Perkins 1206A-E70TTAG2
Type 4 cycle, water-cooled, diesel engine
Compression Ratio 16.1:1
No of Cylinders 6
Cylinders Arrangement In-line
Displacement 8.8 Liters
Bore x Stroke 112 x 149 mm
Prime Rated Power (PRP) 230 kVA/184 kW
Limted Time-Running Power(LTP) 253 kVA/202 kW
Speed 1500 rpm
Governor Electronic
Fuel Consumption 48.6 liter/hour
Rated Current 400 Amps
Rated Voltage 400V/230V
Landuse Type of Unit Low Noise, Automation Type
Weight 2900 Kg
Dimension (LxBxH) 3700 x 1450 x 2200 mm
Rotation Anti-clockwise
 
 
General Specification for silent Generator :
  • Modular Design
  • Anti Corrosion powder coated
  • Insulated with acoustic foam lining
  • Central lifting ring, exhaust pipe can be removed, which is easy to transport
  • Lockable doors with key
  • Protective mesh for rotating parts
  • Exterior emergency stop push button
  • Thermally insulated engine exhaust system
  • Doors fitted on each side
  • Panel observing window
  • Access to the radiator fill or cap
  • Color is optional
  • Fuel gauge or lube drain valve is optional
  • Normal or super soundproof canopy is optional
  • Base frame fuel tank or profile fuel tank is optional
  • The muffler fixed position depend on the output power of the Gen-set 

Silent Generator set Canopy :

  • Specially treated steel sheet
  • Stainless steel locks
  • Control panel viewing window for monitoring the status of the generator set
  • Good ventilation system and anti-heat radiation saturation
  • Effective anti-vibration devices to ensure generator driven steadily
  • Super silent materials inside to ensure the noise lower than 68 dB 7 meters away
  • Emergency stop button mounted outside
  • Side lockable door easy for maintenance and installation
  • Lube oil and cooling water drain pipe to the exterior of the canopy
  • Fuel tank built with level indicator
 Standard equipment  Other configurations
  • Air inlet system
  • Autostart
  • Automatic power switch ATS
  • Automatic power switch and phase-out
  • Automatic fuse magnetothermal
  • Control system
  • Cooling system
  • Fly wheel and flywheel housing
  • Emergency stop button
  • Fuel system
  •  Safety device in the engine for:
    • high water temperature
    • low oil pressure
    • low fuel level 
    • battery charging error
  • Models with different voltage
  • 60 Hz version
   
 Accessories
 
  • Mobile drive wheel
  • Type-approved trailer 
  • Blink-free feedback
  • Parallel operation
  • Fuse type
  • Ground fault switch 
  • Extraction point with power transformer input point
  • Radiostatic protection VDE 0875 curve N
  • Electronic speed control
  • Oil heater
  • Engine heater
  • Oil pump
  • Automatic tanker from external tank
  • Protective frame with lift hook 
  • Container unit 
  • Alternator voltage / frequency generator
  • Fuel tank deployment
  • Fuel level 
  • Alarm on all internet connection.
  • GSM alarm monitoring
  • Capable soundproofing 70dB down to 55dB
  • Remote control
  • Environmental Class STAGE III
  • Disconnect 1-phase or 3-phase, respectively
  • UPS system battery backup 1-phase and 3-phase
Standard Genset Specifications
  
Engine
  • Perkins heavy duty diesel engine
  • 6 cylinder equipped with Water cooling
  • Mechanical governor control system
  • Replaceable wet type cylinder liners
  • Replaceable fuel filter, oil filter and dry element air filter
  • Cooling radiator and fan
  • Fuel connection hoses and manual sump oil drain valve
  • Exhaust silencer
  • Maintenance free battery including rack and cables
  • Jacket water heater (as option)
  • Perkins Engine Manual
 Alternator
  • Brushless, single bearing system
  • Insulation class H with circuit breaker protection
  • Standard degree of protection IP 23
  • Self-exciting and self-regulating
  • Main line circuit breaker
  • Close voltage regulation

Greenpower AB reserves the right to make any errors or changes in specifications. © Copyright / Greenpower AB.

  • GREENPOWER Perkins Diesel Power generator 230kVA 184kW Soundproof canopy Automatic starting
    Art. nr.
    GP230PSAS
    GREENPOWER Perkins Diesel Power generator 230kVA 184kW Soundproof canopy Automatic starting